Overvoltage This is caused by a high intermediate circuit DC voltage. This can arise from high inertia loads decelerating too quickly, the motor turns into a generator and increases the inverter’s DC voltage. There are other causes of DC overvoltage, however. POSSIBLE FIXES: 1. Turn the. .
This is detected by an imbalance of the currents supplying the motor implying a leakage current to earth is present. This is usually caused by poor insulation resistance to earth. POSSIBLE FIXES: 1. Check insulation. .
This occurs when the motor is taking too much current with reference to the value in Group 99, motor data. POSSIBLE FIXES: 1. Check that motor’s load is not excessive. 2. Check. .
We hope you found the information in this article useful if you have a fault not listed and you need technical assistance contact our engineering team by emailing your enquiry to. [pdf]
[FAQS about Stop voltage of inverter]
Integrated Solar & Energy Storage
Solutions Provider
Enter your solar project details and energy storage requirements. We will reply you in 24 hours.